Skip to content
Ok Pool Reform

New pool dehumidifier console for excellent humidity and temperature control

CDP Line v2 pool dehumidifier console: New pool dehumidifier console for excellent control of the humidity and individual temperature of the area, whether in swimming pools or spas.

heated pool with dehumidifier
heated pool with dehumidifier

En Ok Pool Reform within Climatized pool And regarding pool dehumidifiers, we present you a highly recommended option for a specific product: Pool dehumidifier console CDP Line v2 from Astralpool.

Below, we provide you with the official product page: Astralpool CPD LINE v2 pool dehumidifier.

What is the Pool Dehumidifier Console?

What is the Pool Dehumidifier Console?
What is the Pool Dehumidifier Console?

What is the AstralPool CDP LINE 2 Dehumidifier

What is the AstralPool CDP LINE 2 dehumidifier

  • The AstralPool CDP LINE v2 pool dehumidifier is a state-of-the-art piece of equipment that is used to control the individual humidity and temperature of small pools and spas.
  • Available in a wide range of capacities from 2 to 5 l/h, in models with only the dehumidifier or with the option of hot water coil or electric resistance.

What is the new CPD LINE v2 dehumidifying console used for?

Utilities of the CDP Line v2 pool dehumidifier

Firstly, comment that The new CPD LINE v2 dehumidifying console is applied in installations where individual humidity and temperature control of the area is required., taking advantage of the latent heat of vaporization and the equipment's own performance in heating the ambient air of small swimming pools, bathtubs, changing rooms and bathrooms.


Description CDP Line v2 pool dehumidifier console

Description CDP Line v2 pool dehumidifier console
Description CDP Line v2 pool dehumidifier console

CDP Line 2 dehumidifier specifications

When to use the CDP Line v2 dehumidifier

El CDP Line v2 dehumidifier It is used in installations where individual temperature and humidity control of each area is required.

It takes advantage of the latent heat of vaporization and the equipment's own performance to heat the air in the environment of small swimming pools, changing rooms, etc.

Innovations pool dehumidifier console

One of the innovations that this dehumidifier presents is its structure, expanded polypropylene (EPP), which manages to reduce both the weight and the sound level.

Why is the pool dehumidifier console formed?

  • To begin with, the pool dehumidifier is made up of a monoblock evaporator and condenser battery with copper pipes with special aluminum fins for corrosive environments.
  • It also has a hermetic compressor silencer and with internal protection and crankcase resistance.
  • The refrigeration circuit is made of nitrogenous, dehydrated and deoxidized copper.
  • And lastly, the heliocentrigual fans They are more reliable and quieter.

The assembly of the CDP LIne v2 pool dehumidifiers is very simple

  • Assembling and maintaining the device is simple. You can install it quickly and clean the filters and machine easily.
  • You can easily place the device on the wall thanks to its new placement system. Likewise, the new front is light and easy to place.
  • Additionally, if you want to personalize the front with a photograph you can do so.

Stipulations on how pool dehumidifiers work.

All the  general operating conditions 
  • · Installation air temperature: 28ºC
  • · Humidity: 65%
  • · Minimum installation air temperature: 18 ºC

General technical characteristics of CDP pool dehumidifier

General characteristics of CDP pool dehumidifier
General characteristics of CDP pool dehumidifier

How the CDP pool dehumidifier is built

Manufacturing of the CDP pool dehumidification console

  • Initially, the new CDP dehumidifier is built around a polypropylene injection structure, with grilles and outer casing injected in polycarbonate.
  • Likewise, it has a small size so it is also very light.
  • Additionally, the colors do not fade.

Astralpool CDP Dehumidification Console Components

  1. First of all, it consists of independent evaporation and condensation coils, made of copper tube and tempered aluminum fins, specific for corrosive environments.
  2. On the other hand, it comes with a hermetically sealed rotary compressor that includes internal protection.
  3. Additionally, it contains a coolant circuit made of thick-walled copper tubing, processed to repel oxidation.
  4. At the same time, it is a new generation of centrifugal fans, quieter and lighter.
  5. R410-A refrigerant gas, not harmful to the ozone layer.
  6. Finally, it incorporates an expansion valve with pressure balancer.

Control of pool dehumidifier consoles

• New PLC control (Schneider Electric).
• New user interface, via LCD display.
• Modbus capability as standard.

Assembly and installation of pool dehumidifiers

• Easy installation and easy access internal components.
• External connections for gas charging•

Options Pool dehumidifier console

• Post-heating heating elements with safety thermostat.
• Post heating battery with safety thermostat

Dimensions of the pool dehumidifier console

astralpool pool dehumidifier console measurements
astralpool pool dehumidifier console measurements

Pool dehumidifier console

Innovations Externally Pool dehumidifier console

Advances in the dehumidification console for swimming pools

  • New, more attractive design, with simple and elegant lines.
  • New wall placement system, simpler and faster.
  • New, more visible and attractive user interface.
  • New front, lighter and easier to install and uninstall.
  • New customizable front cover with the design chosen by the client. Photographic quality.

Evolutions Internally Pool dehumidifier console

Internal advances in the dehumidification console for swimming pools

  • Redesign of internal components to facilitate accessibility.
  • New generation of more reliable and quiet compressors.
  • New generation of heliocentrifugal fans, more reliable and quieter.
  • New modular internal structure that facilitates the replacement of components.
  • New internal plastic structure that reduces the noise level of the equipment.

What pool dehumidifier do I need?

dehumidifiers for indoor pools
dehumidifiers for indoor pools

Which dehumidifier is better

Which dehumidifier to buy

Features CDP Line-2 DehumidifierCDP Line-3CDP Line-4CDP Line-5
Chap. dehumidification2 l / h3 l / h4 l / h5 l / h
Chap. bat heating water6000w6000w12000w12000w
Chap. bat heating electric4000w4000w5000w5000w
Voltage230 / 50 / R&N230 / 50 / R&N230 / 50 / R&N230 / 50 / R&N
Ventilador1.100 (Centrifugal)1.100 (Centrifugal)1.100 (Centrifugal)1.100 (Centrifugal)
Pressure loss (water)10106060
Pressure loss (air)8080150150
box – structureEPP + POLYCARBONATE + PMMAEPP + POLYCARBONATE + PMMAEPP + POLYCARBONATE + PMMAEPP + POLYCARBONATE + PMMA
Soft DrinkR410-AR410-AR410-AR410-A
water connection1/2"1/2"1/2"1/2"
High pressure alarm24 – 18 ba / 350 – 260 psi24 – 18 ba / 350 – 260 psi24 – 18 ba / 350 – 260 psi24 – 18 ba / 350 – 260 psi
Low pressure alarm0.7 - 2.2 bar / 10 - 32 psi0.7 - 2.2 bar / 10 - 32 psi0.7 - 2.2 bar / 10 - 32 psi0.7 - 2.2 bar / 10 - 32 psi
NoiseLevel 1 m: 62 dB
Level 3 m: 58 dB
Level 1 m: 62 dB
Level 3 m: 58 dB
Level 1 m: 62 dB
Level 3 m: 58 dB
Level 1 m: 62 dB
Level 3 m: 58 dB
Comparison of the CDP Line 2 Dehumidifier models

Operating limits:

air temperatureAir humidity
MIN20˚C / 68˚F45% RH2
MAX35˚C / 95˚F90% RH2
Technical characteristics pool dehumidifier console

More details:

  • IP grade: IP44.
  • Insulation type: Class I
  • Refrigerant Gas: R410-A

Installation of pool dehumidifier console

How to install the pool dehumidifier console equipment

Minimum distances for installation of the pool dehumidification console

installation conditions pool dehumidifier console CDP Line v2
installation conditions pool dehumidifier console CDP Line v2
Minimum distances for pool dehumidifier installation
Minimum distances for pool dehumidifier installation

General dehumidifying console installation rules

  1. Depending on the place where the device must be installed (humid place, etc.), install electrical protection with a 30 mA differential circuit breaker. Otherwise, a shock may occur.
  2. The condensation must be completely evacuated. Otherwise, water could overflow inside the machine and damage the internal components.
  3. Do not leave a damaged installation. The unit could cause an accident.
  4. Do not put anything on top of the unit. An accident could occur due to the falling object.
  5. Check network compatibility with the data indicated on the device.
  6. Install the appliance on a level base to avoid condensation overflows.
  7. Provide easy access to the appliance for maintenance
  8. Install the device outside volume 1.
  9. It is recommended to renew the air in private pools. In public pools it is mandatory.

It is necessary to determine the location of the device according to certain criteria:

  • The appliance must be fixed on a hard base (concrete type or hard steel chassis) and must be protected from flooding risks.
  • A free space must be left around the appliance of the order of 1.0 m in the front and at least 1.0 m at the rear and sides of the appliance.
  • The air caused by the propeller must be directed out of reach of the work environments (windows, doors...). Likewise, do not place anything in front of the air intake/discharge grilles of the equipment.
  • The minimum distance between the dehumidifier and the pool edge must be at least 2,0 m.
  • Electrical and hydraulic connections must be made in accordance with current standards (NF C15 100, CE 1 364). The connection pipes must be fixed.
  • During normal operation of the equipment, water condensation will occur and must be evacuated. All units have an adapter on the side of the base for this purpose, which must always be free of any obstruction.
  • Any incorrect handling can cause serious damage to the unit and the user, which could result in fatal injuries.
  • It is important to remember that no part of the pipe or hose should exceed the level of the drain hole located at the base of the equipment.
  • This condensation water does not have to be treated in a special way.

Condensation drain

Carefully plan an appropriate water drainage slope to ensure a
smooth water flow.

  • Drainage will be done through a siphon.
  • The water drain consists of a translucent rubber hose (20×1mm) and is located on the lower right side of the machine.

Electric connection

electrical supply for pool dehumidifier console
electrical supply for pool dehumidifier console

Power supply conditions for the pool dehumidifier console

  1. The electrical supply for the dehumidifier should preferably come from an exclusive circuit that has regulatory protection components (30 mA differential protection) and a magneto-thermal switch.
  2. The equipment must be connected to a safety ground circuit at the terminal block level.
  3. The cables must be installed correctly so that they do not cause interference (steps in the cable glands).
  4. The equipment is intended for connection to a general 230/2/50Hz power supply with ground connection.
  5. The cable sections must be verified and adapted according to the needs and installation conditions and always following regional and national regulations.
  6. Cables are installed whose section complies with current regulations and prevents them from heating up and a voltage drop. As a guide, the general power table can be used for lengths less than 25 meters.
  7. The acceptable voltage variation tolerance is +/- 10% during operation.
  8. Make the connection according to the electrical diagram included in this manual.
  9. Place a U-curve magneto-thermal switch in the general power connection, which will protect the line in case of a short circuit.
  10. Place a differential switch in the general power connection that will protect the installation against possible ground faults. The differential sensitivity will be at least 30 mA.
  11. Before connecting the equipment, check that the electrical installation is disconnected and there is no voltage between the power supply phases.
  12. Connect the current input cables to the machine input terminals.
  13. Connect the ground cable to the corresponding terminal for this purpose.

Operation of the pool dehumidification console

astralpool cdp line v2 operation
astralpool cdp line v2 operation

computer startup

PLC Controller: User Interface

  • Pressing and holding the “SET” key for 3 seconds will turn the device on or off.
  • The right side of the display shows “OFF” when the unit is off and the room temperature when the unit is on.
  • The hot water supply must be at least 45ºC and no more than 90ºC.
  • The maximum pressure of the water circuit cannot exceed 0,3 MPa (3 bar).
  • Water entry into the battery must be done through the upper tube.
  • The left side of the screen shows the time when the unit is off and the humidity
  • of the environment when the unit is on.
  • Press and hold down the »SET» key to turn the device on/off.

Table to understand the user menu


Press the ''Set'' button with the device on to access the device's submenus:

MenuItemDescription
SPset pointSetpoint adjustment
TimeScheduleTime programming adjustment.
EcoECO settingsEquipment operating mode settings.
Table to understand the dehumidification console user menu

Postheating Regulation

In heating mode, the purpose of the application is to maintain the temperature above a configured value.

  • The regulator receives the temperature value measured by the Ambient probe and compares it with the setpoint (value of the temperature we want to reach.)
  • The heating action is carried out when the temperature is lower than the setpoint minus the marked differential. (Air temperature differential of 1,5ºC. Factory value).
  • If heating is necessary, the equipment activates the electric heaters or the post-heating battery until the set point is reached.
  • In heating mode, limitations are placed on the temperature of the supply air, which establish security against operating anomalies due to overheating of the equipment chamber.
  • If there is any problem of this type, the air heating is deactivated and the temperature is maintained.
  • fan running until this heat is dissipated. If the alarm exists, the icon will appear
  • alarm and it must be reset manually by pressing the “F1” key.

Dehumidification

In dehumidification mode, the purpose of application is to keep the humidity below
of a value configured in Humidity Set point.

  • The regulator receives the humidity value measured by the humidity probe and compares it with the setpoint, which is the humidity setpoint value, plus the marked differential (5% relative humidity differential. Factory value).
  • Dehumidification is carried out through the refrigeration circuit. For the correct operation of this system, a series of requirements must be met.
  • On the one hand, that the safety systems are all correct and that the suction temperature is above 20ºC.
  • If any of these cases are not met, the computer will not start.
  • Appearing the corresponding alarm on the main screen.

Pool dehumidification console maintenance

General maintenance of the appliance is highly recommended

All this, to check its correct operation and maintain its performance and thus be able to avoid future failures, preserving the equipment in good condition.

Therefore, an updated record must be kept of each of the maintenance operations that includes all elements repaired or replaced.

Annual maintenance pool dehumidifier console

Cleaning the filters

  • Wash the filters with warm soapy water, rinse thoroughly and dry.
  • Change if necessary.
pool dehumidification console filter cleaning
pool dehumidification console filter cleaning

Checking the fan and cooling batteries

Pool dehumidifier fan and battery maintenance
Maintenance of the fan and refrigeration batteries

These operations should be carried out at least once a year (more frequently if necessary).
necessary) and includes several elements:

  • Review of security mechanisms.
  • Dust cleaning of electrical components.
  • Checking electrical connections.
  • Checking gas pressure.
  • Checking the drain.

Refrigerant Gas

This equipment uses R410-A as refrigerant gas.

This gas is classified as non-hazardous according to directive 67/548/EEC or 1999/45/EC.

It is non-flammable and has no flash point. R410-A gas has no chlorine content, so it has zero ozone depletion potential (ODP), but contains fluorinated greenhouse gases, covered by the Kyoto Protocol, with a modest global warming potential ( GWP) of

When in a liquid state it can cause freezing due to evaporation.
immediate. Vapor is heavier than air and can cause suffocation.

Below, we provide you with the official product page: Astralpool CPD LINE v2 pool dehumidifier.